BoilerSpection IM Manual Maintenance 25
5 Maintenance
The BoilerSpection™ system is designed to operate continuously in harsh environments, but filter
replacement and other maintenance measures need to be implemented as described in this section
to avoid preventable wear or damage to the system.
5.1 Recommended BoilerSpection Maintenance Schedule
5.1.1 Inspection and Test
Item Description
Tools or Parts
Required
Maintenance Interval
1 Check all cooling systems After each use
2 Check air filters Depends on usage, but check
monthly if used regularly and
replace annually or sooner as
required
5.1.2 Preventive Maintenance
Item Description
Tools or Parts
Required
Maintenance Interval
1 Clean lens tip Kimtech wipes,
Q-tip
Check when image quality
degrades
2 Replace 3 µm 1st stage air
filter, if necessary
Adjustable
wrench
Yearly or as required
3 Replace 0.3 µm 2nd stage air
filter, if necessary
Adjustable
wrench
Yearly or as required
5.2 Spare Parts
The BoilerSpection™ system is designed to operate continuously in harsh environments; however it
is recommended that spare parts be kept in storage in the event of a component failure.
We recommend that you keep the following spare components on-hand:
Item Description LumaSense Part Number
1
Replacement lens tip, 50 FOV
112-0051-01
2 Replacement lens tip, 75° FOV 112-0052-01
3
Additional or Spare Lens, 18" (46 cm) straight,
standard 50° HFOV
812-0046-21